- Intellution’s FIX industrial automation software is a popular Windows-based HMI/SCADA solution which provides process monitoring and control, data collection, graphic display, historical trending, alarming, data archiving, and security for an unlimited number of I/O points. The gateway to FIX software allows client computers to.
- In its time, Intellution’s FIX32 was a powerful automation solution that took full advantage of Windows 95 and Windows NT’s powerful capabilities. UPGRADE INTELLUTION FIX32 V5.5,6.5,7.0 TO PROFICY IFIX V5.5,5.8 OR CURRENT VERSION UPGARDE FIX 32 HMI COMMUNICATION DRIVER,DATABASE,MIMICS AND.
- Intellution rebrands software products To reflect a broader application range served by its newer products, Intellution recently changed the name of its software family from FIX Dynamics to Intellution Dynamics.The firm's new iFIX version 2.1 was released as the first product with the new name.
- Open communication with Eurotherm products and specialized I/O drivers for world leading software packages: Wonderware; Intellution FIX32 and iFIX; Eurotherm provides an OPC Server that can be used to interface a LIN network to any 3rd party OPC client OPC Data Access 2 server. Supports: LIN protocol over Ethernet TCP/IP (ELIN).
. Intellution Software Compatibility Testing FIX 6.15 FIX 7.0 iFIX 2.1 iFIX 2.21 iFIX 2.6 iFIX 3.0 iFIX 3.5 iFIX 4.0 iFIX 4.5 iFIX 5.0. OSIsoft will continue to test new releases of iFIX as they become available. Additional PI Software. REM Intellution Fix DMACS (FIX32) / Dynamics (iFIX) REM.
Acutally, it is more than a reporting tool. It can also archive your process data. Currently this toolkit supports Intellution Fix32 and iFix. It works as a data tunnel between Fix32/iFix and Microsoft Excel. Basically, this toolkit grabs data (real-time or historical data) from Fix32/iFix and then inserts them into MS Excel cells as being configured. The core of this toolkit consists of dozens of executable programs, which can be called inside Fix32 scripts, iFix VAB scripts, externally customized program or even manually through command prompt. This flexibility makes it more user-friendly. However, formally they should be called in a scheduler program like iFix Scheduler so that the reporting process can be fully automated. This toolkit maintains its own timer, counter and register, which will enable users to build more intelligent reports. This toolkit also comes with log file, which will help you with trouble shooting. You know, it is a tool. Depending on how you use it, it may become very powerful! Never know!Why shall I try it? Okay, here is what I think: 1)It is cheap. Forget about Oracle and SQL Server. They are deadly expensive plus unpredictable maintenance expense. Try the software you use everyday and see how much it can save you; 2)You can get a very powerful front-end (user interface). You know the charting function in Excel, you know the flexible format in Excel, and you know powerful macro in Excel. Don't you? If not, give it a try. You can utilize all those powerful tools in Excel for your data storage and reports; 3)Everybody is familiar with Excel. Logically maybe I shall not say everybody. But you know what I mean. You boss does not need to learn new software in order to understand your reports. Shouldn’t you get credit out of it? 4)It is easy to configure. Just take a look at the samples and you will know what I mean. . There is one more reason- it is free.
Intellution Fix32 Software Install
Although I trust my own software, I will NOT be responsible for any damage caused by the mis-operation, etc. Please use it with your discretion. However, since most functions are read-only ( I mean they don't change process values in Fix/iFix. 'FixSetStringVal.exe' and 'FixSetDigitalVal.exe' are exceptional), it would be safe to use this toolkit!
Also, I would like to ask for your help to better this toolkit. Please report any bugs and write any suggestions to me. It is highly appreciated. My email: xiangtaozhao@yahoo.com
Scada Software
Final version: 5.1.6(02/26/2014):- Numericupdown Thousand Separator was added.
- 46 different type SQL query added for reporting tools.
- Print document function was update, Print screen command added.
- Plc communication error function added.
- Decimal place added for scale function.
- Alternative Ip address added for Redundant and all plc communication driver.
5.1.2(11/25/2013): Multiple screen designer update, many function added.
5.1.1(10/08/2013): Redundant working style was added. Please visit our blog for more information. http://www.scadasoftware.net/redundant/
5.0.4(03/20/2013): Scada object Backcolor, Forecolor, Enable, Visible and Text property compare method added. Omron Fins Ethernet protocol added. Webserver with password protection or without protection select function added.
5.0.0(02/21/2013): Please visit our blog for more information. http://www.scadasoftware.net/wintr-scada-version-5-0-0-features/
Intellution Fix 32 Software Download
- Alarms and Warnings can be defined for process values. When alarm or warning occurred, it can be monitored in the Screen real time and informed to E-Mail and SMS recipients.
- Easily creates detailed Reports from historical datas and saves them in Excel or PDF format..
- With Recipe, previously saved values for the tags are send to the devices by one click.
- For creating advanced Screen interfaces, WinTr contains; Symbol Factory software which contains 4000 industrial symbol in 60 category, Dundas’s elegant Chart(Real Time, Historical, Pie, Line, Bar, 3D) and Gauge(Circular, Numeric, Linear, Knob) objects,
- Microsoft .NET Framework’s Button, CheckBox, RadioButton, Combobox, NumericUpDown, Horizantal ScroollBar, Vertical ScrollBar, ProgressBar, Datagridview, DateTimePicker, TabControl, GroupBox, PictureBox, TextBox, Toolstrip objects.
- Unlimited flexibility withVisual Basic and C# scripting.
- Uses Microsoft SQL Serverfor(2005,2008,2012) databases. Limited 4gb, unlimited table and each table limited 950 Tags.
- With Server-Client option WinTr stations can be run synchronously through Internet and Screens can be monitored on remote computers by web browsers such as Internet explorer.
- WinTr Scada Software is sold with 3 years free upgrade warranty.
- WinTr Scada Software development is free, runtime and development are sold together.
- WinTr Scada Software users are given indefinite free technical support. (By email other than Turkey)
- You buy WinTr Scada Software license when you deliver your project to your customer after the completing your project. (With Demo license only first symbol of symbol factory can be used.)
- Many other scada softwares are not developed in .NET platform. .NET platform born in 2003. However WinTr Software is developed at .NET 2008. Thus development is very easy. Moreover it is compatible with Windows 7 and other operating systems that will be released. New Operating systems are released .NET framework compatible.
- Many .NET objects that can not be found other SCADAs presented in WinTR. Thus your project get out of Windows 95 look and gets Vista apperiance.
- We are taking to your service 2009 years award winning chart object dundas chart and gauge. WinTr is the only scada software that uses this variation and visuality.
- Reaching Scada variables is very easy with SQL Input/Output tags. You can reach easily with other programs that you developed or internet browsers or excel. Many scada software export data to excel. WinTr can do this too. But the method mentioned here is different. In this method, scada never reaches excel. Excel reaches to scada via excel macro.
- VB and C# scripts are work completely different. Scada softwares has a restrictions at script functions. However Wintr has no restrictions you can perform many operations by writing scripts almost as if developing program on .NET platform.
- It is possible to reach and modify scada informations other than the scada tags with scripts. When such needs occur we provide information our customers freely. We develop needed scripts for our customers some case free some case with fee.
- Scripts are compiled once at first then saved as .Net DLL. Then runs directly. Thus they run faster. Even huge amount operations can run very fast in the script.
- At many scada software, the function number which can be run by a button or other object are limited. However 256 function can be run with WinTr Scada Software Also you can trigger this functions when alarm occured or gone.
- Thousands WinTr scada may establish full or restricted access to each other via server and client functionality.
- Can be connected to automation devices via S7 MPI, PPI, Profinet, Host-Link and modbus RTU without OPC server.
- E-mail and SMS sent when specified conditions occur.
- You can create many different recipe algorithms with categorized recipe.
- Real time data monitoring and control can be done with real time working feature which achieved version 2.0.0
- First going Runtime mode at high number tags may be slow. Then all objects connects each other as interrupt and only works when values changed. Thus you can develop high tag count projects for slow computers. High number means 20000 tag and upper.
- Beside many image file you can use animated gif images in scada pages.
- We present all of this excelent features with low price.
Buy now!
You Tube:How to make first scada project ? , Scada general features , How to make reports in scada? , How to get print out from the scada? , How to set scada as server & client? , How to use web server feature of scada?
Model & Price
Function | Starter | Basic | Proffesional | Ultimate |
Development & Runtime | X | X | X | X |
Realtime & Historical Trend | X | X | X | X |
Gauge | X | X | X | X |
.Net Component Object | X | X | X | X |
Cutaway | X | X | X | X |
Symbol Factory | X | X | X | X |
Alarm Management | X | X | X | X |
Vb & C# Script | X | X | X | X |
Database Support (4 gb.) | X | X | X | X |
Opc Client | X | X | X | X |
Plc Communication Driver | X | X | X | |
Recipe | X | X | X | |
Reporting | X | X | ||
Sms | X | X | ||
X | X | |||
Printing (Barcode) | X | X | ||
Barcode Reader | X | X | ||
Excel Support | X | X | ||
Pdf Support | X | X | ||
WinTr Server & Redundant | X | |||
Web Server (Ready Only) | X | |||
EventView | X | |||
ActiveX, Dll, .Net component Support | X |
Tag | Starter | Basic | Professional | Ultimate |
64 | 128 Usd. | 228 Usd. | 478 Usd. | 728 Usd. |
128 | 256 Usd. | 356 Usd. | 606 Usd. | 856 Usd. |
256 | 512 Usd. | 612 Usd. | 862 Usd. | 1112 Usd. |
512 | 768 Usd. | 868 Usd. | 1118 Usd. | 1368 Usd. |
1024 | 1024 Usd. | 1124 Usd. | 1374 Usd. | 1624 Usd. |
2048 | 2048 Usd. | 2148 Usd. | 2398 Usd. | 2648 Usd. |
65534 | 4096 Usd. | 4196 Usd. | 4446 Usd. | 4696 Usd. |
Dongle price 25 Usd.
- Upgrading price is amount of the difference between new licence and current licence. With new version licence upgrade is processed by the application that arranged for you. These application’s price is 50 usd.
- You need a two identical(same configuration) licence for fully backed up working of two computer(redundant). Client-Server architecture is different than Redundant system. Client reads tag value from the server. The 64 Tag client can read all values of 65534 tag server. On the client side tags which read from server are considered as ‘internal’ tag. On the other hand redundant system works one on one synchronize. If one computer disabled all operation taken on the other computer.